Task 1: Mounting the J930s Unit in a Rack

The VTrak J930s unit installs into your rack using the supplied mounting rail kit.
Before you start, verify that you have these rack-mount components:
Rack rails (one left and one right)
Rail installation hardware (screws, guides, and bars)
Enclosure rails (one left and one right)
The rails are marked R for right and L for left, viewing from the front of the enclosure.
Mounting the Enclosure in a Rack
To install the J930s enclosure into a rack:
1. Loosen the screws on the left and right rack rails and adjust the lengths
accordingly to match the depth of the rack. Then re-tighten the screws.
2. Secure the rack rails to the front and rear supports of the rack, using the screws
and hardware as shown below.
Figure 1. Left rack rail, front view
Figure 2. Left rack rail, rear view
3. Tighten all screws securing the rack rails into the rack.
4. Position the enclosure rails on each side of the J930s unit with the rails over the
five keyhole tabs. Then slide the enclosure rails into place. See Figure 3.
Figure 3. Side rails attached to the J930s unit
5. Anchor the rail to each side of the J930s unit as shown below using a single
screw. See Figure 3.
6. Lift the J930s unit and place it in the rack with the guide blocks on top of the rails.
This action removes some of the weight while connecting the rails from the rack
to the enclosure. See Figure 4.
Figure 4. Guide blocks rest on top of the side rails
7. Carefully engage the enclosure rails into the rack rails and slide the J930s unit
into the rack in until you hear a click. See Figure 5.
The click indicates that the enclosure rail tabs are locked into place.
Figure 5. Enclosure and rack rails
8. Push the J930s unit all the way into the rack.
This completes mounting your J930s unit in the rack.

Task 2: Installing the Front Bezel

To install the bezel onto the front of the J930s unit:
1. Squeeze the two release tabs on the front of the J930s unit. See Figure 6.
2. Carefully pull the J930s out of the rack until the enclosure rail tabs engage.
Figure 6. Front of the J930s unit without bezel
3. Hold the bezel with the lightpipe assembly at the bottom. Position the bezel so
the alignment pins on the J930s unit slide into the alignment guides on the inside
of the bezel. See Figure 7.
Figure 7. Inside view of the bezel
4. Insert the screws through the ears on each side of the J930s unit.
Two screws on each side. Gently tighten the screws. See Figure 8.
Figure 8. Attaching the bezel to the J930s unit
5. Press the green rail tabs on either side of the J930s.
6. Carefully push the J930s into the rack until the two release tabs engage.

Task 3: Installing the Cable Management Kit

The J930s unit includes a cable management kit to organize your and SAS and power
cables in the rack. The cable guides enable you to slide the J930s unit out of the rack
without disconnecting or tangling your cables.
You must install the J930s unit in the rack before you can install the cable
management kit.
To install the cable management kit:
1. Attach one end of each cable guide as shown below to the rear of the enclosure
using the attached thumbscrews. See Figure 9.
Figure 9. Cable guides attached to rear of a J930s unit
2. Attach the other end of cable guides to the rack rails using the pins from rack rail
kit. See Figure 10.
Figure 10.Cable hardware attached to rear of rack.
3. Route the SAS and power cables through the cable management rails as shown
below.
The cable management rails have slots for plastic ties or Velcro cable wraps to
hold the cables in place. See Figure 11.
Ties and wraps are not included.
Figure 11.Cable guide with SAS and power cables installed
4. Test the cable management system by sliding the J930s unit all the way out on
the rails. Ensure that the unit moves smoothly and that there are no cables loose
or binding when the system is slid back into the rack.
This completes the installation of the cable management kit.

Task 4: Installing Physical Drives

The VTrak J930s JBOD expansion unit supports:
3.5-inch and 2.5-inch form factor
SAS drives, 6 Gb/s and 3 Gb/s
Hard disk drives (HDDs) and solid state drives (SSDs)
Supports any mix of SAS and SATA drives simultaneously in the same enclosure
For a list of supported physical drives, download the latest compatibility list from the
PROMISE support web site.
Assembling Drive Carriers for 3.5-inch Drives
For 2.5-inch drives, see Chapter 2 of the VTrak J930s Product Manual.
The drive carrier consists of two parts, a release rail and a pivot rail, plus the attaching
screws.
To assemble a drive carrier:
1. Attach the release rail to the physical drive with two screws, as shown in
Figure 12.
The drive’s data/power connector is at the bottom.
2. Position the carrier pivot rail to the physical drive so that Tab A on the release rail
inserts into Slot B on the pivot rail.
3. Attach the pivot rail to the physical drive with two screws.
4. Tighten the drive carrier screws to 4 to 6 inch-pounds (0.45 to 0.67 Nm).
Do not over-tighten.
This completes drive carrier assembly. See Figure 13.
Warning
Before you begin, read the VTrak VTJ930s – Warning and Caution
Notice document.
Rack rail attached at the front the rack
Rack rail attached at the rear of the rack
Keyhole tabs
Attaching screw
J930s unit
Top of rack rail
Enclosure guide block
Latch release tab
Rack rail
Enclosure rail
Release tabs
Bezel alignment pins
Bezel alignment pins
Bezel alignment guides
Lightpipe assembly
This side down
Screw
Bezel
Ear
Screw
Mounting pins
(1 on each side)
Rack rail
Power and SAS cables Install cable wraps here

Manual

Consultați aici manualul pentru Promise Technology J930S, gratuit. Acest manual se încadrează în categoria Servere și a fost evaluat de 1 persoane cu o notă medie de 6.5. Acest manual este disponibil în următoarele limbi: Engleză. Aveți o întrebare despre Promise Technology J930S sau aveți nevoie de ajutor? Puneți întrebarea aici

Aveți nevoie de ajutor?

Aveți o întrebare despre Promise Technology J930S și răspunsul nu se află în manual? Puneți întrebarea aici. Furnizați o descriere clară și cuprinzătoare a problemei și a întrebării dvs. Cu cât problema și întrebarea dvs. sunt descrise mai bine, cu atât le va fi mai ușor celorlalți proprietari Promise Technology J930S să vă ofere un răspuns bun.

Numărul de întrebări: 0

Specificații Promise Technology J930S

Mai jos veți găsi specificațiile produsului și specificațiile manuale ale Promise Technology J930S.

General
Brand Promise Technology
Model J930S | F40J93S06010000
Produs Server
EAN 704118090631, 0704118090631
Limbă Engleză
Tipul fișierului Manual de utilizare (PDF)
Medii de stocare
Discuri de stocare instalate Da
Tip discuri de stocare instalate HDD
Număr de discuri de stocare instalate 60
Capacitate stocare totală instalată 180 TB
Tipuri discuri de stocare suportate HDD & SSD
Număr de discuri de stocare suportat 60
Capacitate de stocare maxim suportată - TB
Interfață discuri de stocare SCSI Serial Atașat (SAS)
Capacitate discuri de stocare 3000 Giga Bites
Capacitate discuri de stocare 2.5/3.5 "
Suport RAID Da
Niveluri RAID 0,1,5,6,10,50,60,JBOD
Drive bay-uri tip hot-swap Da
Viteza de rotaţie a HDD 7200 RPM
Procesor
Familia de procesoare -
Procesor -
Memorie
Memorie internă - Giga Bites
Tip de memorie internă -
Reţea
Ethernet LAN Nu
Wi-Fi Nu
Client DHCP -
Server DHCP -
Conexiune
Porturi Ethernet LAN (RJ-45) -
Port USB Nu
Număr porturi USB 2.0 0
Cantitate porturi USB 3.2 Gen 1 (3.1 Gen 1) Tip-A 0
Porturile canal Fibre 4
Porturi externe mini-SAS 4
Design
Tip de sasiu Cabinet metalic (4U)
Culoarea produsului Gri
Tipul de răcire Activ
Material carcasă -
Ecran încorporat Nu
Performanță
Tipul Server stocare
Clasă dispozitiv -
Funcție back-up Da
Caracteristici back-up Cloud,iSCSI LUN
Software
Sistem de operare cu condiţia -
Managementul energiei
Capacitate unitate de alimentare cu energie (PSU) 1200 W
Redundant sursa de alimentare (RPS) sprijin Da
Tensiune AC intrare 90-264 V
Frecvență de intrare AC 47/63 Hz
Curent de ieşire 14.5 A
Greutate şi dimensiuni
Lățime 420.6 milimetri
Adâncime 891.5 milimetri
Înălţime 175.3 milimetri
Greutate 96800 g
Conditii de mediu
Interval de temperatură de funcţionare (T-T) 10 - 35 °C
Interval relativ operaţional de umiditate 10 - 80 %
Temperatură de depozitare (T-T) -40 - 70 °C
Umiditate relativă la depozitare (H-H) 5 - 95 %
Şoc de operare 5 G
Non-şoc de operare 10 G
Vibraţii de operare 0.15 G
Non-vibraţii de operare 0.5 G
Detalii tehnice
Certificate de sustenabilitate RoHS
Certificate
Certificare WEEE, 80Plus
Alte caracteristici
Sisteme de operare compatibile OS X/OS X Server (10.8), Microsoft Windows Server 2008 w/SP2, Microsoft Windows Server 2008 R2, Windows Server 2012, RedHat Enterprise Linux 6.2, RedHat Enterprise Linux 6.3, SuSE Linux Enterprise Server 11.2, VMware ESX Server 5.1, Vmware
Afișați mai multe

Întrebări frecvente

Nu puteți găsi răspunsul la întrebarea dvs. în manual? Puteți găsi răspunsul la întrebarea dvs. în Întrebările frecvente despre Promise Technology J930S de mai jos.

Întrebarea dvs. nu se regăsește aici? Puneți întrebarea aici

Fără rezultate